01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Powertrain Management06 Transmission and Drivetrain07 Brakes and Traction Control08 Starting and Charging09 Power and Ground Distribution10 Steering and Suspension11 Heating and Air Conditioning12 Restraint Systems13 Accessories and Optional Equipment14 Body and Frame15 Cruise Control16 Instrument Panel, Gauges and Warning Indicators17 Lighting and Horns18 Windows and Glass19 Wiper and Washer Systems
Kia Soul L4-2.0L (2010)03 · Maintenance
03 · Maintenance

Refrigerant: Specifications (page 3 of 4)

Make
Kia
Model
Soul
Engine
L4-2.0L
Year
2010
Section
Fluids › Refrigerant
MaintenanceSpecifications · page 3 of 4
background image

3. If the low-pressure does not reach more than 93.3 kPa (700 mmHg, 27.6 in.Hg) in 10 minutes, there is probably a leak in the system. Partially

charge the system, and check for leaks (see Leak Test.).

4. Remove the low pressure valve from the low-pressure service port.

System charging

Use only service equipment that is U.L-listed and is certified to meet the requirements of SAE J2210 to remove HFC-134a(R-134a) from the air
conditioning system.

CAUTION:

-

Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or throat.

-

Be careful when connecting service equipment.

-

Do not breathe refrigerant or vapor.

If accidental system discharge occurs, ventilate work area before resume of service.
Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.

1. Connect an R-134a refrigerant Recovery/Recycling/Charging System (A) to the high-pressure service port (B) as shown, following the equipment

manufacturer's instructions.

2. Add the same amount of new refrigerant oil to system that was removed during recovery. Use only specified refrigerant oil. Charge the system

with 19.4±0.88 oz. (550±25g)of R-134a refrigerant. Do not overcharge the system the compressor will be damaged.

Refrigerant leak test

Always conduct a leak test with an electronic leak detector whenever leakage or refrigerant is suspected and when conducting service operations which
are accompanied by disassembly or loosening or connection fittings.

NOTE:

In order to use the leak detector properly, read the manual supplied by the manufacturer.

If a gas leak is detected, proceed as follows:

1. Check the torque on the connection fittings and, if too loose, tighten to the proper torque. Check for gas leakage with a leak detector (A).
2. If leakage continues even after the fitting has been tightened, discharge the refrigerant from the system, disconnect the fittings, and check their

seating faces for damage. Always replace, even if the damage is slight.

3. Check the compressor oil and add oil if required.
4. Charge the system and recheck for gas leaks. If no leaks are found, evacuate and charge the system again.

Pinch or Ctrl + scroll to zoom. Double-tap to reset.

Parts & tools for this job For 2010 Kia Soul 2.0L

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.