Door Lock Relay: Testing and Inspection
Keyless Entry and Burglar Alarm

Door Lock Relay

Inspection

Door Lock Relay

Check for continuity between the terminals.

1. There should be continuity between the No.1 terminals in the I/P-F and No.6 terminals in the I/P-H when power and ground are connected to the

No.1 terminals in the I/P-F and No.3 terminals in the I/P-H.

2. There should be no continuity between the No.1 terminals in the I/P-F and No.6 terminals in the I/P-H when power is disconnected.

Door Unlock Relay

Inspection

Door Unlock Relay

Check for continuity between the terminals.

1. There should be continuity between the No.1 terminals in the I/P-F and No.5 terminals in the I/P-H when power and ground are connected to the

No.1 terminals in the I/P-F and No.9 terminals in the I/P-H.

2. There should be no continuity between the No.1 terminals in the I/P-F and No.5 terminals in the I/P-H when power is disconnected.