Spectra L4-20L (2004) Condenser HVAC Component Locations
Condenser HVAC: Service and Repair
REPLACEMENT
1. Recover the refrigerant with a recovery/recycling/charging station.
2. Drain the coolant, about 1L from the radiator.
3. Remove the nuts(A), then disconnect the discharge line and condenser line from the condenser. Plug or cap the lines immediately after
disconnecting them to avoid moisture and dust contamination.
4. Remove the condenser fan.
5. Disconnect the upper hose(B) from the radiator(A).
6. Remove the radiator fan.
7. Remove the bolts(A), then remove the upper mount brackets(B) from the radiator.