Spectra L4-2.0L (2004)
Starter Brush: Testing and Inspection
INSPECT STARTER BRUSH
Brushes that are worm out, or oil-soaked, should be replaced.
STARTER BRUSH HOLDER TEST
1. Check that there is no continuity between the (+) brush holder (A) and (-) brush holder (B). If there is no continuity, replace the brush holder
assembly.
2. Insert the brush (A) into the brush holder, and bring the brush into contact with the commutator, then attach a spring scale (B) to the spring (C).
Measure the spring tension at the moment the spring lifts off the brush.
Spring tension 13.7 - 19.6N (1.4 - 2.0 kg, 3.09 - 4.41 lb)