kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Fluid - A/T > < Transaxle - Tester Connection
Page 1
background image

Differential Case: Adjustments

DIFFERENTIAL CASE PRELOAD ADJUSTMENT 

Place a solder (approximately 10 mm (0.4 inch) in length, 3 mm (0.12 inch) in diameter) on the torque converter housing as shown in the figure.

Install the torque converter housing to the transmission case without applying sealant. Tighten its mounting bolts to the specified torque. Loosen the
bolts, and remove the solder(A). Use a micrometer to measure the thickness (T) of the pressed solder(A).

Select a - spare which thickness is within the following value.

Standard value: (T+0.045 mm(0.0018 inch)) to (T+0.105 mm(0.0041 inch))

Fluid - A/T > < Transaxle - Tester Connection