Spectra GS L4-1.8L (2002)
Refrigerant Oil: Description and Operation
Compressor oil
The oil used to lubricate the compressor circulates in the system while the compressor is operating. Whenever replacing any component of the system or
when a large amount of gas leakage occurs, add oil to maintain the original total amount of oil.
Compressor oil quantity: 150 cc ± 10 cc
Handling of oil
1. The oil should be free from moisture, dust, metal filings, etc.
2. Do not mix oils.
3. The moisture content in the oil increases when exposed to the air for prolonged periods. After use, seal the container immediately.
Oil return operation
To check the oil level or add the oil, idle engine for 20 - 30 minutes by setting the control set to maximum cooling and blower level, to
return the lubricant to compressor.