6. When the hazard lamp is on during the LOCK/UNLOCK by the remote control, the LOCK/UNLOCK signal by the remote control shall be

ignored.

5. CRASH DOOR UNLOCK

1. If IG1 is on and a crash signal is received, send an unlock pulse to the door locks.
2. This function is prior in all door lock functions.
3. If door lock switch is locked in door lock switch is unlocked state, after the first crash unlock output, issue unlock pulse for again 5 sec.

4. Only one crash unlock can occur during one ignition on cycle.

6. IGNITION KEY REMINDER

1. If the key is in the ignition and the driver's door or assist door is open and the vehicle is locked using driver's knob or assist knob, then the

central locking system will issue an unlock pulse of duration 1 second to the all doors, thus preventing locking of the vehicle.

2. If a Knob remains locked, then the central locking shall issue a maximum of 3 pulses of 0.5 second duration to unlock the vehicle. If during

these pulses, the door lock knob becomes unlocked, stop the next pulse.

3. If during the 3 pulses door is closed or the key is removed, stop the next pulse.
4. If after the 3 unlock pulses the knob remains in the locked state, the condition is remembered. 1 sec unlock (reset) pulse is issued if there is a

change in any of the following inputs: Door warning switch, driver door switch, assist door switch, driver door lock switch, assist door lock
switch.

5. If a door is open and locked and a key is inserted, issue one unlock pulse of duration 1 sec. (At KEY is inserted after driver seat unlock in 2

turn UNLOCK vehicle, no issue one unlock pulse)

6. When Door is closed in 0.5 seconds after LOCK, an unlock pulse of duration 1sec shall be issued.
7. When is Power window main switch LOCK, issue one unlock pulse immediately after 0.5 second LOCK. ( Key warning switch = Keyless

switch)

8. To further prevent locking of keys in ignition, a guard time of 0.5 seconds is introduced after a door is closed. When key is in ignition and the

door changes from open to close and a lock occurs within 0.5 sec, an unlock pulse of duration 1 sec shall be issued.

Diagram Information and Instructions|Page 27 > < Diagram Information and Instructions|Page 25