01 Introduction02 General specification data03 Engine tuning data04 General fitting reminders05 Lubricants, fluids and capacities06 Maintenance07 Engine08 Emission control09 Fuel system10 Cooling system11 Manifold and exhaust system12 Transfer gearbox13 Automatic gearbox14 Rear axle and final drive15 Front axle and final drive16 Steering17 Brakes18 Chassis and body19 Air conditioning20 Electrical21 Instruments
Land Rover Defender V8i Workshop Manual Supplement19 · Air conditioning
19 · Heating & A/C

Refrigeration system faults system check

Make
Land Rover
Model
Defender V8i Workshop Manual Supplement
Section
Fault diagnosis › Refrigeration system faults system check
Air conditioningRefrigeration system faults system check

REFRIGERATION SYSTEM FAULTS System check

For any refrigeration system to function properly all The following conditions should be checked after components must be in good working order. The unit operating the system for several minutes: cooling cycle and the relationship between air discharge temperature and ambient temperature and the pressures at the compressor can help to determine proper operation of the system. The length of any cooling cycle is determined by such factors as ambient temperature and humidity, thermostat setting, compressor speed and air leakage into the cooled area, etc. With these factors constant, any sudden increase in the length of the cooling cycle would be indicative of abnormal operation of the air conditioner. The low and high side pressures at the compressor will vary with changing ambient temperature, humidity, in-car temperature and altitude. The following items should be checked before operating the system:

  1. Compressor drive belt tension.
  2. Compressor magnetic clutch operation.
  3. Condenser fan operation.
  4. Condenser fins, dirt will cause poor cooling and higher operating temperatures.
  5. All high pressure lines and components should be hot to the touch.
  6. All low pressure lines should be cool to the touch.
  7. Inlet and outlet temperatures at the receiver/drier should be at the same temperature (warm). Any very noticeable temperature difference indicates a blocked receiver/drier.
  8. Heavy frost on the inlet to the expansion valve may indicate a defective valve or moisture in the system.
  9. Evaporation air temperature will vary with ambient temperature and humidity. As humidity increases the outlet temperature will be higher.