landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Diagnosis And Testing|Page 2209 > < Diagnosis And Testing|Page 2207
Page 3
background image

Refrigerant 
pressure sensor 
signal 

0.5V at zero 
pressure rising to 
4.8V at 
approximately 
3.2MPa when 5V 
seen at C2655-1 

B1A6211 

9990 

Compressor not 
running, no cooling 
available 

Input 

Short circuit to 
ground 

RH sunlight 
sensor signal 

0V in darkness/low 
light rising to 5V in 
bright sunlight. 
Should never 
exceed 5V (C1629-
13) 

None 

9962 

No solar 
compensation, 
customer too hot in 
sunlight 

Input 

Open circuit, 
short circuit to 
ground 

RH sunlight 
sensor signal 

0V in darkness/low 
light rising to 5V in 
bright sunlight. 
Should never 
exceed 5V (C1629-
13) 

B1A6312 

9962 

Maximum solar 
compensation, 
blower level too 
high 

Input 

Short circuit to 
5V 

Cavity not used  n/a 

n/a 

n/a 

n/a 

n/a 

n/a 

Blower relay 
coil 

<1V with ignition 
and ATC module 
panel on 

None 

99A2 

Blower runs 
continuously 

Output 

Short circuit to 
ground 

Blower relay 
coil 

<1V with ignition 
and ATC module 
panel on 

None 

99A2 

Blower inoperative  Output 

Open circuit, 
short to 12V 

Cavity not used  n/a 

n/a 

n/a 

n/a 

n/a 

n/a 

Medium speed 
CAN bus low 

n/a 

U1A1449 

9959, 
see 
Note 
below 

ATC module does 
not work 

Input 

CAN 
initialisation 
failure - open 
circuit 

Medium speed 
CAN bus low 

n/a 

U030055 

9959, 
see 
Note 
below 

ATC module does 
not work 

Input 

CAN 
configuration 
failure - short 
circuit to ground 

Medium speed 
CAN bus low 

n/a 

U007388 

9959, 
see 
Note 
below 

ATC module does 
not work 

Input 

CAN bus off - 
short circuit to 
12V 

10 

Medium speed 
CAN bus high 

n/a 

U1A1449 

9959, 
see 
Note 
below 

ATC module does 
not work 

Input 

CAN 
initialisation 
failure - open 
circuit 

10 

Medium speed 
CAN bus high 

n/a 

U030055 

9959, 
see 
Note 
below 

ATC module does 
not work 

Input 

CAN 
configuration 
failure - short 
circuit to ground 

10 

Medium speed 
CAN bus high 

n/a 

U007388 

9959, 
see 
Note 
below 

ATC module does 
not work 

Input 

CAN bus off - 
short circuit to 
12V 

11 

Pollution sensor 
supply 

Battery voltage 
when rear A/C 
control panel on. 0V 
when panel in sleep 
mode 

B1B7015 

99A2 

Pollution sensor 
and rear A/C 
control panel 
inoperative 
(Discovery 3 only) 

Output 

Open circuit 

11 

Pollution sensor 
supply 

Battery voltage 
when rear A/C 
control panel on. 0V 
when panel in sleep 
mode 

B1B7311 

99A2 

Pollution sensor 
and rear A/C 
control panel 
inoperative 
(Discovery 3 only) 

Output 

Short circuit to 
ground 

Diagnosis And Testing|Page 2209 > < Diagnosis And Testing|Page 2207