landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4497 > < Diagram Information and Instructions|Page 4495
Page 1
background image

Alternator: Description and Operation

GENERATOR

The Generator has a power control module voltage regulator for use in a 14V charging system with 6÷12 zener diode bridge rectifiers.

The ECM (engine control module) monitors the load on the electrical system via PWM (pulse width modulation) signal and adjusts the generator output
to match the required load. The ECM (engine control module) also monitors the battery temperature to determine the generator regulator set point. This
characteristic is necessary to protect the battery; at low temperatures battery charge acceptance is very poor so the voltage needs to be high to maximize
any rechargeability, but at high temperatures the charge voltage must be restricted to prevent excessive gassing of the battery with consequent water loss.

The Generator has a smart charge capability that will reduce the electrical load on the Generator reducing torque requirements, this is implemented to
utilize the engine torque for other purposes. This is achieved by monitoring three signals to the ECM (engine control module) :

^

Generator sense (A sense), measures the battery voltage at the CJB (central junction box).

^

Generator communication (Alt Com) communicates desired Generator voltage set point from ECM (engine control module) to Generator.

^

Generator monitor (Alt Mon) communicates the extent of Generator current draw to ECM (engine control module) This signal also transmits faults
to the ECM (engine control module) which will then sends a message to the instrument pack on the CAN (controller area network) bus to
illuminate the charge warning lamp.

Diagram Information and Instructions|Page 4497 > < Diagram Information and Instructions|Page 4495