landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Brake Fluid Accumulator|Testing and Inspection|Page 6318 > < Transfer Case - Will Not Shift/MIL ON|Page 6312
Page 1
background image

Brake Fluid Accumulator: Testing and Inspection

ACCUMULATOR PRECHARGE- CHECK 

The diaphragm type accumulator is precharged with nitrogen at 80 bar (1160 inch lbs.), its function is to store hydraulic energy. Over a period of
years, a normal loss of precharge will occur. This procedure will indicate the extent to which precharge pressure has fallen.

NOTE:  A new accumulator at 20?C has a ` nominal pressure of 80 bar (1160 inch lbs.). Minimum acceptable pressure is 50 bar (725 inch lbs.).

1. Depressurize braking system.
2. Remove 3 nuts securing pump/motor assembly to valance. Raise assembly from mounting to allow clearance for pressure test adapter.

3. Remove banjo bolt securing high pressure hose to pump. Collect sealing washers.
4. Connect pressure gauge to pump using LRT-70-003 through high pressure hose union.

NOTE:  Use original sealing washers.

5. Switch ignition on. Observe pressure gauge.

Brake Fluid Accumulator|Testing and Inspection|Page 6318 > < Transfer Case - Will Not Shift/MIL ON|Page 6312