landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Level Control Solenoid Valve|Service and Repair > < Level Control Solenoid Valve|Specifications
Page 1
background image

Level Control Solenoid Valve: Description and Operation

VALVE BLOCK 

The valve block controls the direction of air flow. Air flow to and from the air springs is controlled by seven solenoid operated valves, one for
each spring plus an inlet, exhaust and outlet. In response to signals from the Electronic Control Unit (ECU) , the valves allow high pressure air to
flow in or out of the air springs according to the need to increase or decrease pressure. A diaphragm valve operated by the solenoid outlet valve
ensures that all exhausted air passes through the air dryer.

Mounted on the valve block is a pressure switch which senses air pressure and signals the ECU to operate the compressor when required. The
compressor will operate when the pressure falls between 7.2 and 8.0 bar.  It will cut out at a rising pressure of between 9.5 and 10.5 bar. 

The valve block contains the following serviceable components: solenoid coils 1 to 6, drive pack and pressure switch. The valve block must only
be dismantled after the correct diagnosis procedure.

Level Control Solenoid Valve|Service and Repair > < Level Control Solenoid Valve|Specifications