7. Withdraw the side cover to expose the electric wires to the fan motor and resistance unit.
8. Release the resistance unit by tensioning back the metal mounting straps
9. Remove the side cover feeding the electrical leads and the multiplug through the hole.

10. Remove the ten spring clips, three circlips and the two screws that secure the halves of the heater casing together. Ensure all fasteners and foam

gaskets are removed.

Flap Positioning

11. Position the flap (A) as shown, pry and slide its lower edge through the gap between motor housing and outer case. While separating each half of

the heater casing.

12. Note the location of the air flap pivots, for reassembly.

Blower Motor

13. The motor assembly is held into the left half of the casing by two plastic tabs, locate and pry them away from the motor.
14. Note for reassembly the position and layout of the electrical wiring. Then withdraw the motor assembly including attached wires and resistance

unit from its housing.

REFIT

1. Feed the wiring and resistance unit through the motor housing and fit the motor assembly. Ensure the wires are positioned correctly, to avoid

entangling the rotor, and the plastic tabs locate to secure the motor.

2. Mark a white spot on the end of each air flap pivot to be reassembled into the heater casing.
3. Offer the heater casing halves together. Ensure the flap (A) is positioned to reverse instruction 11.
4. Point the remaining air flap pivots in the direction of their location.
5. Locate and slot into the left casing the heater control panel assembly. Examine closely to ensure that both fasteners engage and slide into their

housing.

6. Slowly and firmly push the casing halves together checking that all components are aligned. Any solid resistance felt suggests a component not

locating correctly Rectify and continue until the casing halves are together.

7. Refit all of the fasteners holding the heater casing halves together.
8. Reverse removal instructions 4 to 9.
9. Connect the rod to the vent control lever to its marked position.

10. Check all controls operate and flaps seal against the heater casing.
11. Refit the left duct to footwell outlet.
12. Renew the foam gaskets.
13. Refit the heater assembly.