HIGH-TENSION CORDS REMOVAL AND INSTALLATION
REMOVAL
1. Remove V-Bank cover.
2. Disconnect high-tension cords from spark plugs.
(a) Using needle-nose pliers, disconnect the cord clamp from the engine wire protector.
(b) Disconnect the high-tension cords at the rubber boot. Do not pull on the cords.
NOTICE: Pulling on or bending the cords may damage the conductor inside.
(c) Disconnect the high-tension cords from the clamp.
3. Disconnect high-tension cords from ignition coils.
(a) Using a screwdriver, lift up the lock claw and disconnect the holder from the ignition coils.
(b) Disconnect the high-tension cord at the grommet.
DO NOT pull on the cord.
NOTICE:
-
Pulling on or bending the cords may damage the conductor inside.
-
Do not wipe any of the oil from the grommet after the high-tension cord is disconnected.