ES 300 V6-3.0L (1MZ-FE) (1997)
Low Speed:
Connect the positive (+) lead from the battery to terminal I and the negative (-) lead to terminal 5, check that the motor operates at low speed.
If operation is not as specified, replace the motor.
High Speed:
Connect the positive (+) lead from the battery to terminal 4 and the negative (-) lead to terminal 5, check that the motor operates at high speed.
If operation is not as specified, replace the motor.
Stopping at Stop Position:
a. Operate the motor at low speed and stop the motor operation anywhere except at the stop position by disconnecting positive (+) lead from
terminal 1.
b. Connect terminals 1 and 3.
c. Connect the positive (+) lead from the battery to terminal 2 and negative (-) lead to terminal 5, check that the motor stops running at the stop
position after the motor operates again.
If operation is not as specified, replace the motor.