CHECK CAN BUS LINE (CAN-L) FOR SHORT TO +B
CIRCUIT DESCRIPTION
A short to the +B is suspected in the CAN bus line when there is continuity between terminals 16 (BAT) and 14 (CANL) of the DLC3.
Wiring Diagram
CHECK CAN BUS LINE (CAN-L) FOR SHORT TO +B
CIRCUIT DESCRIPTION
A short to the +B is suspected in the CAN bus line when there is continuity between terminals 16 (BAT) and 14 (CANL) of the DLC3.