a. Install the cooler condenser with the 4 bolts.

Torque: 5.0 N.m (51 kgf.cm, 44 in.lbf)

HINT:  If the condenser is replaced with a new one, add compressor oil to the new condenser.

Capacity: 40 cc (1.4 fl. oz.)

Compressor oil: ND-8 or equivalent

2. INSTALL DISCHARGE HOSE SUB-ASSEMBLY

a. Remove the vinyl tape attached to the pipe and connecting part of the cooler condenser.
b. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.

Compressor oil: ND-OIL 8 or equivalent

c. Install the O-ring on the discharge hose.

d. Install the discharge hose on the cooler condenser with the bolt.

Torque: 5.4 N.m (55 kgf.cm, 47 in.lbf)

3. INSTALL LIQUID TUBE SUB-ASSEMBLY A

a. Remove the vinyl tape attached to the pipe and connecting part of the cooler condenser.
b. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.

Compressor oil: ND-OIL 8 or equivalent