lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Brake Pedal Assy|Adjustments|Page 6621 > < Brake Pedal Assy|Adjustments
Page 2
background image

(8) Turn the stop light switch assembly so that its protrusion is between 0.5 and 2.4 mm (0.020 to 0.095 in.). Tighten the lock nut.

Torque: 17 N*m (170 kgf*cm, 12 ft.*lbf)

(9) Connect the connector to the stop light switch.

(c)

Adjust the brake pedal stroke sensor.
(1) Connect the intelligent tester to the DLC3.
(2) Loosen the 2 nuts.

(3) Turn the power switch ON (IG). While reading the stroke sensor 1 value shown on the intelligent tester, turn the stroke sensor slowly to

the right and left to adjust it to the standard voltage.
Standard voltage: 0.8 to 1.2 V

NOTICE:  Do not depress the brake pedal after turning the power switch ON (IG).

(4) Tighten the 2 nuts.

Torque: 8.5 N*m (87 kgf*cm, 75 in.*lbf)

(d) Perform system initialization.

2. CHECK BRAKE PEDAL FREE PLAY

(a)

Depress the brake pedal several times until no vacuum is left in the booster.

(b) Press the pedal until a slight resistance is felt. Measure the distance as shown in the illustration.

Maximum pedal free play: 2.0 mm (0.079 in.)
If the pedal free play is 1 mm (0.04 in) or less, check the protrusion of the stop light switch shaft.
Protrusion of the stop light switch shaft: 0.5 to 2.4 mm (0.020 to 0.095 in.)
If the protrusion is off the specified value, adjust it. If the protrusion is within the specified value, it is normal. However, brake pedal free play
is 1.0 mm (0.039 in.) or less.

Brake Pedal Assy|Adjustments|Page 6621 > < Brake Pedal Assy|Adjustments