front of the radiator.

-

Never apply water directly onto the electronic components.

HINT:  If the vehicle has or had a water leakage problem, the leakage may have damaged the ECU or connections. Look for evidence of
corrosion or short circuits. Proceed with caution during water tests.

d. HIGH ELECTRICAL LOAD METHOD:

When a malfunction seems to occur when the electrical load is excessive.

1. Turn on the heater blower, headlights, rear window defogger and all other electrical loads. Check if the malfunction reoccurs.

(2006/07- )

SYMPTOM SIMULATION 

HINT:  The most difficult case in troubleshooting is when no problem symptoms occur. In such a case, a thorough problem analysis must be carried out.
A simulation of the same or similar conditions and environment in which the problem occurred in the customer's vehicle should be carried out. No matter
how much skill or experience a technician has, troubleshooting without confirming the problem symptoms will lead to important repairs being
overlooked and mistakes or delays.

For example: 
With a problem that only occurs when the engine is cold or as a result of vibration caused by the road during driving, the problem can never be
determined if the symptoms are being checked on a stationary vehicle or on a vehicle with a warmed up engine. Vibration, heat or water penetration
(moisture) is difficult to reproduce. The symptom simulation tests below are effective substitutes for the conditions and can be applied on a stationary
vehicle.

Important points in the symptom simulation test: In the symptom simulation test, the problem symptoms as well as the problem area or parts must be
confirmed. First, narrow down the possible problem circuits according to the symptoms. Then, connect the tester and carry out the symptom simulation
test, judging whether the circuit being tested is defective or normal. Also, confirm the problem symptoms at the same time. Refer to the problem
symptoms table for each system to narrow down the possible causes.