1. Disconnect connectors A and C and measure the resistance between them.

HINT:  Measure the resistance while lightly shaking the wire harness vertically and horizontally. If the results match the examples above, an
open circuit exists between terminal 1 of connector A and terminal 1 of connector C.

2. Disconnect connector B and measure the resistance between the connectors.

If the results match the examples above, an open circuit exists between terminal 1 of connector B2 and terminal 1 of connector C.

c. Check the voltage.

Diagram Information and Instructions|Page 3540 > < Diagram Information and Instructions|Page 3538