GX 470 V8-4.7L (2UZ-FE) (2004)
SST 09730-00010
NOTICE: Refer to Service Precautions.
b. Remove the 2 O-rings, the plate and the connector No.2.
4. REMOVE HEIGHT CONTROL RESERVOIR ASSY
a. Remove the 2 bolts and the height control reservoir assy.
5. INSTALL HEIGHT CONTROL RESERVOIR ASSY
a. Install the height control reservoir assy with the 2 bolts.
Torque: 29 Nm (300 kgf-cm, 21 ft. lbs.)
6. CONNECT HEIGHT CONTROL TUBE NO.7
a. Install 2 new O-rings, a new plate, a new connector No.2, and connect the height control tube No.7.
NOTICE: Refer to Service Precautions.
7. CONNECT HEIGHT CONTROL TUBE NO.6
a. Install 2 new O-rings, a new plate, a new connector No.2, and connect the height control tube No.6.
NOTICE: Refer to Service Precautions.
8. CONNECT HEIGHT CONTROL TUBE NO.2
a. Coat 2 new O-rings with MP grease.
b. Push the height control tube No.2 in straight to connect it until the clip makes "click" sound.
c. Install the holder.
9. INSPECT AIR LEAK