GX 470 V8-4.7L (2UZ-FE) (2004)
Shift Interlock Solenoid: Testing and Inspection
INSPECTION
1. INSPECT KEY INTER LOCK SOLENOID
a. Disconnect the solenoid connector.
b. Connect KLS+ (4) terminal to the batteries, positive (+) terminal, and KLS- (3) terminal to the battery negative (-) terminal, and apply about
12V between KLS+ - KLS- terminals. Check that operation noise can be heard from the solenoid.
If the solenoid does not operate, replace the solenoid.