Shift Interlock Solenoid: Testing and Inspection

INSPECTION 

1. INSPECT KEY INTER LOCK SOLENOID

a. Disconnect the solenoid connector.
b. Connect KLS+ (4) terminal to the batteries, positive (+) terminal, and KLS- (3) terminal to the battery negative (-) terminal, and apply about 

12V between KLS+ - KLS- terminals. Check that operation noise can be heard from the solenoid.
If the solenoid does not operate, replace the solenoid.