(b) Disengage the wire harness clamp.
19. SEPARATE FRAME WIRE
CAUTION:
Wear insulated gloves.
NOTICE:
*
Insulate the removed terminals with insulating tape.
*
Do not allow any foreign objects or water to enter the inverter with converter assembly.
(a) Remove the bolt.
(b) Disconnect the wire harness clamp and frame wire.
20. TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY
(a) Temporarily install the connector cover with the bolt to prevent any foreign objects or water from entering the inverter with converter
assembly.
21. DISCONNECT LOW VOLTAGE CONNECTOR
NOTICE:
*
Insulate the removed terminals with insulating tape.
*
Do not allow any foreign objects or water to enter the inverter with converter assembly.
(a) Raise the lock lever and disconnect the low voltage connector.
(b) Disconnect the low voltage connector from the inverter with converter assembly.
22. REMOVE INVERTER WITH CONVERTER ASSEMBLY
CAUTION:
Wear insulated gloves.
(a) Remove the 2 bolts, nut and inverter with converter assembly.