lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Front Door Window Regulator|Service and Repair > < Front Door Window Regulator|Inspection|Page 5410
Page 2
background image

NOTICE:
Match the arrow mark of the probe with the direction of the current flow.

(2) Fully close the door glass by pulling up the power window regulator switch assembly. Wait for approximately 60 seconds.

(3) Continue to pull up the power window regulator switch assembly and measure how long it takes for the electrical current to change from a

range of 16 to 28 A to approximately 1 A (current shut-off inspection).

Standard:

4 to 90 seconds

If the result is not as specified, replace the power window regulator motor assembly RH.

(4) Wait for 60 seconds after the previous step, and then push down the power window regulator switch assembly.

OK:

The front RH side window goes down.

If the result is not as specified, replace the power window regulator motor assembly RH.

Front Door Window Regulator|Service and Repair > < Front Door Window Regulator|Inspection|Page 5410