lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 5600 > < Symptom Related Diagnostic Procedures|Page 5598
Page 3
background image

(5) When the key is placed on the driver seat or front passenger seat cushion, check that the wireless door lock buzzer sounds.

HINT
Place the key on the driver or front passenger seat cushion.

(b) Diagnostic mode inspection (indoor electrical key oscillator (for rear floor))

(1) Connect the Techstream to the DLC3.

(2) Turn the engine switch on (IG).

(3) Turn the Techstream on.

(4) Enter the following menus: Body Electrical / Smart Access / Utility / Communication Check (Key Diag Mode) / Overhead + Rear

Room.

(5) When the key is placed on the rear seat cushion, check that the wireless door lock buzzer sounds.

HINT
*

Place the key on the rear seat cushion.

*

If the buzzer sounds, it can be determined that the indoor electrical key oscillators are operating normally.

Result:

C --  REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)  See: Accessories and Optional Equipment/Antitheft and
Alarm Systems/Alarm Module/Service and Repair/Removal

B --  CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - INDOOR ELECTRICAL KEY OSCILLATOR)
A -- Continue to next step.

5. CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - INDOOR ELECTRICAL KEY OSCILLATOR)

(a) Disconnect the certification ECU (smart key ECU assembly) connector.

(b) Disconnect the indoor electrical key oscillator (for front floor) connector.

(c) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Symptom Related Diagnostic Procedures|Page 5600 > < Symptom Related Diagnostic Procedures|Page 5598