Brake Lamp Relay: Testing and Inspection

LIGHTING (EXT): STOP LIGHT CONTROL RELAY: INSPECTION

1. INSPECT STOP LIGHT CONTROL RELAY

(a) Disconnect the J89 stop light control relay connector.

(b) Measure the voltage according to the value(s) in the table below.

Standard Voltage:

Text in Illustration

If the result is not as specified, there is a malfunction on the wire harness side.

(c) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

If the result is not as specified, there is a malfunction on the wire harness side.

(d) Reconnect the J89 stop light control relay connector.

(e) Measure the voltage according to the value(s) in the table below.

Standard Voltage:

Text in Illustration