IS 250C V6-2.5L (4GR-FSE) (2011)
Text in Illustration
Standard Resistance:
(b) Connect a positive (+) lead to the terminal of the solenoid valve connector, and a negative (-) lead to the solenoid body, then check the
operation of the valve.
OK:
The solenoid makes an operating sound.
If the resistance is not within the specified range, replace the shift solenoid valve SR.
8. INSPECT SHIFT SOLENOID VALVE SLT
(a) Measure the resistance according to the value(s) in the table below.
Text in Illustration
Standard Resistance:
(b) Connect a positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the
operation of the valve.
OK:
The solenoid makes an operating sound.
If the resistance is not within the specified range, replace the shift solenoid valve SLT.
9. INSPECT SHIFT SOLENOID VALVE SLU
(a) Measure the resistance according to the value(s) in the table below.