IS 350 V6-3.5L (2GR-FSE) (2006)
a. This method uses a manifold gauge set to locate problem areas. Read the manifold gauge pressure when the conditions are established. Test
conditions:
-
Temperature at the air inlet is 30 to 35 degrees C (86 to 95 degrees F).
-
Engine is running at 1,500 rpm.
-
All doors are fully open.
-
Blower speed control switch is at HI.
-
Temperature control switch is at MAX. COOL.
-
A/C switch is ON.
Gauge readings (Reference)
1. Normally functioning refrigeration system