lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Radiator Cooling Fan Control Module|Locations|Page 3421 > < Radiator Cooling Fan Control Module|Locations|Page 3419
Page 3
background image

Front View Of Wire Harness Connector (to Cooling Fan ECU)

(e)

Check the input voltage.
(1) Disconnect the cooling fan ECU connector.
(2) Turn the engine switch on (IG). Check the voltage of the A9-3 (+B1) terminal on the wire harness side.

Standard voltage: 1 to 14 V
If the result is not as specified, check the power source system (H-fuse, fuse, wire harness and relay).

(3) Connect the cooling fan ECU connector.

(f)

Check wire harness (Cooling fan ECU and body ground).
(1) Disconnect the cooling fan ECU connector.
(2) Measure the resistance of the A9-1 (E1) and body ground.

Standard resistance: Below 1 Ohms
If the result is not as specified, check the wire harness or connector.

(3) Connect the cooling fan ECU connector.

(g) Check the cooling fan motor.

If the result is not as specified, replace the cooling fan motor.

(h) Check the cooling fan motor operation.

(1) Disconnect the cooling fan ECU connector.
(2) Connect the battery to the cooling fan ECU at terminals 3 (+B1) and 1 (E1).
(3) Check that the cooling fan motor rotates.

If it does not operate, replace the cooling fan ECU.

Radiator Cooling Fan Control Module|Locations|Page 3421 > < Radiator Cooling Fan Control Module|Locations|Page 3419