lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Camshaft Oil Control Valve|Page 3236 > < Component Inspection|Page 3233
Page 1
background image

Variable Valve Timing Actuator: Service and Repair
Camshaft Oil Control Valve

REMOVAL

1. REMOVE COWL TOP VENTILATOR LOUVER RH
2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:  Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt
pretensioner activation.

NOTE:  After the engine switch is turned off, the HDD navigation system requires approximately 6 minutes to record various types of memory
and settings. As a result, after turning the engine switch off, wait 6 minutes or more before disconnecting the cable from the negative (-) battery
terminal.

3. REMOVE V-BANK COVER SUB-ASSEMBLY
4. REMOVE AIR CLEANER INLET COVER
5. REMOVE NO. 1 AIR CLEANER INLET

6. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (for Bank 1)

a. Disconnect the oil control valve connector.
b. Remove the bolt and oil control valve.
c. Remove the O-ring from the oil control valve.

7. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (for Bank 2)

a. Disconnect the oil control valve connector.
b. Remove the bolt and oil control valve.
c. Remove the O-ring from the oil control valve.

INSTALLATION

1. INSTALL CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (for Bank 1)

a. Apply a light coat of engine oil to a new O-ring, and install it to the oil control valve.