a. Remove the bolt and disconnect the cooler refrigerant liquid pipe from the cooler condenser.

NOTE:
-

When loosening the bolt, do not allow any tools to contact the pipe.

-

When loosening the bolt, hold a part of the pipe near the connector.

b. Remove the O-ring from the cooler refrigerant liquid pipe.

NOTE:  Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.

31. REMOVE COOLER CONDENSER ASSEMBLY

a. Remove the 4 bolts and cooler condenser.

32. REMOVE COOLER DRYER

a. Using a 14 mm socket hexagon wrench, remove the cap from the modulator.