lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Condenser HVAC|Testing and Inspection|Page 9855 > < Condenser HVAC|Testing and Inspection|Page 9853
Page 11
background image

Torque: 4.1 N.m (42 kgf.cm, 36 in.lbf)

2. INSTALL COOLER CONDENSER ASSEMBLY

a. Install the cooler condenser with the 4 bolts.

Torque: 5.0 N.m (51 kgf.cm, 44 in.lbf)

3. CONNECT LIQUID TUBE SUB-ASSEMBLY

a. Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.
b. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.

Compressor oil: ND-OIL 8 or equivalent

c. Install the O-ring to the cooler refrigerant liquid pipe.
d. Install the cooler refrigerant liquid pipe to the cooler condenser with the bolt.

Torque: 5.4 N.m (55 kgf.cm, 48 in.lbf)

NOTE:
-

When tightening the bolt, do not allow any tools to contact the pipe.

-

When tightening the bolt, hold a part of the pipe near the connector.

4. CONNECT DISCHARGE HOSE SUB-ASSEMBLY

a. Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.
b. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the hose joint.