Solar Sensor: Testing and Inspection
Solar Sensor (For Front Side)
INSPECTION
INSPECT SOLAR SENSOR
Connect the battery's positive (+) lead to terminal 6 and the negative (-) lead to terminal 3, then measure the voltage between the terminals.
NOTE: The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above.
HINT:
-
As the inspection light is moved away from the sensor, the voltage increases.
-
Use an incandescent lamp for inspection. Bring it within 30 cm (11.8 in.) of the A/C solar sensor.
If the result is not as specified, replace the solar sensor.