lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Component Inspection|Page 5135 > < Variable Valve Timing Actuator|Locations|Page 5132
Page 1
background image

Variable Valve Timing Actuator: Testing and Inspection
Component Inspection

INSPECTION

1. INSPECT CAMSHAFT TIMING OIL CONTROL ASSEMBLY

a. Measure the resistance between the terminals.

Standard resistance: 6.9 to 7.9 ohms at 20 °C (68 °F)

If the result is not as specified, replace the oil control valve.

b. Connect the battery's positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.

OK: If the result is not as specified, replace the oil control valve.

NOTE:  Do not allow foreign matter to contact the oil seal face of the oil control valve (connecting surface with cylinder head cover
sub-assembly).

HINT:  If the valve cannot return properly because of foreign matter, a small pressure leak in the advanced direction may occur and a DTC
may be output.