1. Pinch the retainer and then raise it.

NOTE:
-

Do not use any tools in this procedure.

-

Check for any dirt and foreign matter contamination in the valve and around the connector. Clean if necessary. Foreign matter may
damage the O-rings or cause leaks in the seal between the valve and connector.

-

Do not allow any scratches or foreign objects on the parts when disconnecting the tube.

-

Do not forcibly bend, twist or turn the nylon tube.

-

Protect the disconnected part by covering it with a plastic bag after disconnecting the tube.

-

If the tube connector and pipe are stuck, push and pull to release them.

b. Disconnect the purge line hose from the pipe.

c. Disconnect the connector (leak detection pump).

d. Remove the 4 bolts, 2 plastic nuts and canister.