lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Components|Page 11239 > < Components|Page 11237
Page 1
background image

Alarm Module: Service and Repair
Removal

ENGINE IMMOBILIZER: CERTIFICATION ECU: REMOVAL

REMOVAL

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt
pretensioner activation.
NOTICE:
-

After the engine switch is turned off, the HDD navigation system requires approximately 6 minutes to record various types of memory and
settings. As a result, after turning the engine switch off, wait 6 minutes or more before disconnecting the cable from the negative (-) battery
terminal.

-

When disconnecting the cable, some systems need to be initialized after the cable is reconnected  See: Testing and
Inspection/Programming and Relearning/Repair Instruction - Initialization.

2. REMOVE INSTRUMENT SIDE PANEL LH See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and

Repair/Removal

3. REMOVE NO. 1 INSTRUMENT CLUSTER MOULDING See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service

and Repair/Removal

4. REMOVE NO. 1 INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY See: Body and Frame/Interior Moulding / Trim/Dashboard /

Instrument Panel/Service and Repair/Removal

5. REMOVE CERTIFICATION ECU

(a) Disconnect the 2 connectors.
(b) Remove the nut and ECU.

Components|Page 11239 > < Components|Page 11237