lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Secondary Injector Relay > < Engine Compartment|Page 3417
Page 1
background image

Main Relay (Computer/Fuel System): Testing and Inspection

1UR-FSE ENGINE CONTROL SYSTEM: CIRCUIT OPENING RELAY: ON-VEHICLE INSPECTION

ON-VEHICLE INSPECTION

1. REMOVE COWL TOP VENTILATOR LOUVER RH See: Starting and Charging/Charging System/Alternator/Service and Repair/Removal
2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt
pretensioner activation.
NOTE:
After the engine switch is turned off, the HDD navigation system requires approximately 6 minutes to record various types of memory and
settings. As a result, after turning the engine switch off, wait 6 minutes or more before disconnecting the cable from the negative (-) battery
terminal.

3. REMOVE CIRCUIT OPENING RELAY (C/OPN)

(a) Remove the circuit opening relay from the engine room No. 2 relay block.

4. INSPECT CIRCUIT OPENING RELAY

(a) Measure the resistance according to the value(s) in the table below.

Standard resistance:

If the result is not as specified, replace the relay.

5. INSTALL CIRCUIT OPENING RELAY
6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
7. INSTALL COWL TOP VENTILATOR LOUVER RH See: Starting and Charging/Charging System/Alternator/Service and Repair/Installation
8. PERFORM INITIALIZATION

(a) Perform initialization See: Testing and Inspection/Programming and Relearning/Repair Instruction - Initialization.

NOTE:
Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.

Secondary Injector Relay > < Engine Compartment|Page 3417