LS 460 RWD V8-4.6L (1UR-FSE) (2010)
PROCEDURE
1. CHECK DISPLAY SETTING
(a) Check that the display is not in "Screen off" mode.
OK:
The display setting is not in "Screen off" mode.
NG -- CHANGE SCREEN TO "SCREEN ON" MODE
OK -- Continue to next step.
2. CHECK IMAGE QUALITY SETTING
(a) Check that the screen color quality can be set.
OK:
Setting is possible.
NG -- CHECK CABIN
OK -- PRESS PANEL SWITCH "DISPLAY" AND SET SCREEN COLOR QUALITY TO NORMAL
3. CHECK CABIN
(a) Check that condensation is not likely to occur in the cabin, and that the temperature is not high or extremely low in the cabin.
HINT
*
A humid cabin and a rapid change in temperature may lead to condensation. Condensation in the cabin may cause a short circuit.
*
The appropriate cabin temperature is 20 to 30°C (68 to 86°F).
OK:
Condensation is not likely being produced and the temperature is not high or extremely low.
NG -- HEAT OR COOL CABIN TO APPROPRIATE TEMPERATURE AND/OR DRY CABIN
OK -- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE See: Problem Symptoms Table
Cannot Call In A Certain Place
AUDIO / VISUAL: ELECTRO MULTI VISION SYSTEM: Cannot Call in a Certain Place
- Cannot Call in a Certain Place
INSPECTION PROCEDURE
PROCEDURE
1. CHECK SURROUNDING CONDITIONS
(a) Check if the cellular phone can make calls in the place where the problem occurred.
OK:
The cellular phone can make calls.
NG -- END (CELLULAR PHONES CAN ONLY FUNCTION IN CELLULAR SERVICE AREAS)
OK -- Continue to next step.
2. CHECK RECEPTION
(a) Press the "INFO" switch and then select "Phone".