(a) While heating the retainer using a dryer, pull the retainer lightly and remove the double-sided tape. Then remove the retainer.
Heating temperature:
40 to 60°C (104 to 140°F)
CAUTION: Be careful of burns.
(b) Using a cloth or non-residue solvent, wipe off any tape residue on the bumper cover.
Installation
PARK ASSIST / MONITORING: ULTRASONIC SENSOR (for Front Side): INSTALLATION
INSTALLATION
1. INSTALL NO. 1 ULTRASONIC SENSOR RETAINER
(a) Clean the bumper cover.
NOTICE:
-
When there is any dirt such as oil, dust and tape residue on the bumper cover, wipe it off using cloth, gauze, etc. that is soaked with
non-residue solvent.
-
Wipe the cover in one direction.
(b) Determine the center of the sensor installation position.
(1) Wrap the rubber part of the sensor tip with masking tape 3 or 4 times.
NOTICE:
-
Wrap masking tape so that there is no clearance between the sensor and tape, as shown in the illustration.
-
Wrap the tape so that it has no wrinkles.
HINT: To make the tape application easier, lightly fold the tape so that it is roughly the shape of the sensor.