Disposal
BRAKE CONTROL: BRAKE ACTUATOR: DISPOSAL
DISPOSAL
1. DISPOSE OF BRAKE ACCUMULATOR PUMP
(a) Using a drill, slowly make a hole at the circumference of the inner circle of the caution label and discharge the gas.
-
Drill the hole approximately 10 mm (0.394 in.) deep.
-
The gas is nitrogen which is colorless, odorless, and harmless.
CAUTION: Be sure to wear protective glasses as fragments may fly out due to pressure.