(e) Remove the bolt, 3 nuts, inverter bracket and inverter with converter assembly.
-
Since the inverter with converter assembly is very heavy, 2 people are needed to remove the inverter with converter assembly. When
removing the inverter with converter assembly, do not damage the parts around it.
-
To prevent damage, do not hold the inverter with converter assembly by the connectors.
-
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
25. REMOVE NO. 1 INVERTER COOLING HOSE ASSEMBLY
(a) Remove the 2 clips, clamp, No. 1 inverter cooling hose assembly and No. 1 inverter cooling inlet hose from the inverter with converter
assembly.
-
Do not deform, bend or scratch the pipes of the inverter with converter assembly. The pipes are made of aluminum and must remain
undamaged to maintain proper seal with the rubber hoses.
-
The inverter hose is connected to the cooling system built into the inverter. Do not apply excessive force to the inverter hose, or the
inverter cooling system may be damaged.
26. REMOVE NO. 2 INVERTER BRACKET
(a) Remove the 2 bolts and No. 2 inverter bracket from the inverter with converter assembly.
27. REMOVE NO. 3 INVERTER BRACKET
(a) Remove the 2 bolts and No. 3 inverter bracket from the inverter with converter assembly.
28. REMOVE NO. 6 INVERTER BRACKET