LS 600h V8-5.0L (2UR-FSE) Hybrid (2008)
(a) Connect the frame wire to the inverter with converter assembly with the bolt.
Torque: 8.0 Nm (82 kgf-cm, 71 in-lbf)
10. CONNECT GENERATOR CABLE
CAUTION: Wear insulating gloves.
(a) Connect the generator cable to the inverter with converter assembly.
(b) Secure the generator cable to the inverter with converter assembly with the 5 bolts.
Torque: 8.0 Nm (82 kgf-cm, 71 in-lbf)
NOTICE:
-
When installing the bolts that secure the cable, do not damage anything inside the inverter with converter assembly.
-
Make sure that no foreign matter is present on the terminal block.
-
Be sure to tighten the bolt to the specified torque. Failure to do so may damage the bolt.
11. CONNECT MOTOR CABLE
CAUTION: Wear insulating gloves.
(a) Connect the motor cable to the inverter with converter assembly.
(b) Secure the motor cable to the inverter with converter assembly with the 5 bolts.
Torque: 8.0 Nm (82 kgf-cm, 71 in-lbf)
NOTICE:
-
When installing the bolts that secure the cable, do not damage anything inside the inverter with converter assembly.
-
Make sure that no foreign matter is present on the terminal block.
-
Be sure to tighten the bolt to the specified torque. Failure to do so may damage the bolt.
(c) Install the motor cable bracket with the 3 bolts.
Torque: 8.0 Nm (82 kgf-cm, 71 in-lbf)
12. INSTALL INVERTER TERMINAL COVER