LS 600h V8-5.0L (2UR-FSE) Hybrid (2008)
Catalytic Converter Bypass Valve Vacuum Switch: Testing and Inspection
2UR-FSE EMISSION CONTROL: HYDROCARBON ADSORBER CATALYST SWITCHING VALVE: INSPECTION
INSPECTION
1. INSPECT HYDROCARBON ADSORBER CATALYST SWITCHING VALVE
(a) Measure the resistance according to the value(s) in the table below.
Standard resistance:
If the result is not as specified, replace the hydrocarbon adsorber catalyst switching valve.
(b) Check operation of the hydrocarbon adsorber catalyst switching valve.
(1) Check that air does not flow from port E to the filter.