Steering Angle Sensor: Testing and Inspection
Power Steering System

POWER STEERING: POWER STEERING SYSTEM: CALIBRATION

CALIBRATION

1. ROTATION ANGLE SENSOR VALUE INITIALIZATION AND TORQUE SENSOR ZERO POINT CALIBRATION

NOTE: Clear the rotation angle sensor calibration value, initialize the rotation angle sensor value, and calibrate the torque sensor zero point if
any of the following has occurred:
-

The power steering ECU has been replaced.

-

The power steering gear assembly has been replaced.

-

Steering effort differs between left and right.

(a) Inspection before calibration.

(1) Connect the intelligent tester or Techstream to the DLC3.
(2) Turn the power switch ON (IG).
(3) Turn the intelligent tester or Techstream on.

Intelligent tester - Select "IG SUPPLY" from the Data List.
Techstream - Select "IG Supply" from the Data List.

(4) Check the IG power supply voltage on the tester screen.

1

Intelligent tester

EMPS

2

Techstream

EMPS

Standard voltage:
11 to 14 V

NOTE: If the IG power supply voltage is less than 11 V, calibration cannot be performed. In this case, charge or replace the auxiliary battery,
and then perform calibration.

(b) Clearing rotation angle sensor calibration value, rotation angle sensor value initialization, and torque sensor zero point calibration.

NOTICE:
-

If DTC C1516 (Torque Sensor Zero Point Adjustment Incomplete) is stored, the torque sensor zero point cannot be calibrated. Clear the
DTC before starting calibration.

-

If DTC C1526 (Motor Rotation Angle Sensor Initialization Incomplete) is stored, the rotation angle sensor value cannot be initialized.
Clear the DTC before starting initialization.

(1) Connect the intelligent tester or Techstream to the DLC3.
(2) Turn the power switch ON (IG).
(3) Turn the intelligent tester or Techstream on.

Intelligent tester - Select "TRQ SENSOR ADJ".
Techstream - Select "Torque Sensor Adjustment".

(4) Follow the procedures on the tester display to clear the rotation angle sensor calibration value, initialize the rotation angle sensor value,

and calibrate the torque sensor zero point.

NOTICE:
-

When initializing the rotation angle sensor value, observe the following to stabilize sensor voltage:
After turning the power switch ON (IG), wait for at least 2.5 seconds before turning the steering wheel. Do not turn the steering wheel
quickly.