lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Component Inspection|Page 8594 > < Component Inspection|Page 8592
Page 8
background image

a. Connect the positive (+) lead from the battery to terminal 3 and the negative (-) lead to terminal 2.
b. Attach a current-measuring probe to either the positive (+) lead or the negative (-) lead, and check that the current changes from approximately 3.2

A to less than 0.5 A within 20 to 70 seconds.

c. Disconnect the leads from terminals.
d. Approximately 60 seconds later, reverse the polarity, and check that the door lock moves to the LOCK position.

If operation is not as specified, replace the door lock assembly.

Component Inspection|Page 8594 > < Component Inspection|Page 8592