3.

Compare O2S test results with the specified O2S Failure Threshold Chart. It may be necessary to convert O2S test results to a specific
measurement unit using the conversion factor that is supplied in the specified table. See example.

Example:

A.

The Diagnostic Tester displays 17" as a value of the Time $81" (see illustration).

B.

Find the Conversion Factor value of "Time $81"in the O2S Failure Threshold chart. 0.3906 is specified for Time $81 in this chart.

C.

Multiply 17" in step A" by 0.3906 (Conversion Factor) in step "B." 17 x 0.3906 = 6.6%

D.

If the answer is within the Standard Value of TEST LIMIT, the Time $81" can be confirmed to be normal.

NOTE:

^

"LOW SW V" indicates the O2S voltage when the O2S status changes from rich to lean.

^

"HIGH SW V" indicates the O2S voltage when the O2S status changes from lean to rich.

^

If the O2S voltage is lower than "LOW SW V," the O2S status is lean.

^

If the O2S voltage is higher than "HIGH SW V," the O2S status is rich.

NOTE:

Before the O2S Monitor completes or after the ignition switch is turned OFF, the Diagnostic Tester displays the viewable upper limit or a
lower limit of the test value (example: 0 V, 1.275 V, os [seconds], 10.2s, 0 and 255).