RX 400h AWD V6-3.3L (3MZ-FE) Hybrid (2007)
2. INSTALL SERVICE VALVE
a. Apply sufficient compressor oil (ND-OIL 11) to a new O-ring and the fitting surface of the electric inverter compressor.
Compressor oil: ND-OIL 11 or equivalent.
NOTE:
-
Do not use any compressor oil other than ND-OIL 11 or equivalent.
-
If any compressor oil other than ND-OIL 11 or equivalent is used, electric inverter compressor insulation performance may decrease,
resulting in leakage of electric power.
b. Install the O-ring onto the service valve.
c. Install the service valve No.1 with the bolt.
Torque: 9.8 N.m (100 kgf.cm, 87 in.lbf)
3. INSTALL ELECTRIC INVERTER COMPRESSOR
a. Install the electric inverter compressor with the 3 bolts.
CAUTION: Tighten the bolts in the order indicated in the illustration.
Torque: 25 N.m (255 kgf.cm, 18 ft.lbf)