lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 6059 > < Initial Inspection and Diagnostic Overview|Page 6057
Page 9
background image

(a) Turn the power switch off.

(b) Connect the Techstream to the DLC3.

(c) Turn the power switch on (IG) and wait for 10 seconds.

(d) Turn the Techstream on.

(e) Perform "Health Check" using Techstream and check that Telematics (Safety Connect) is listed on "Health Check Result"    See: Initial

Inspection and Diagnostic Overview/Safety Connect System/Health Check.

Result:

B --  PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE  See: Symptom Related Diagnostic
Procedures/Safety Connect System/Problem Symptoms Table
A -- Continue to next step.

2. CHECK DTC

(a) Turn the power switch off.

(b) Connect the Techstream to the DLC3.

(c) Turn the power switch on (IG) and wait for 10 seconds.

(d) Turn the Techstream on.

(e) Check current DTC and history DTCs    See: Reading and Clearing Diagnostic Trouble Codes.

Result:

B --  GO TO DIAGNOSTIC TROUBLE CODE CHART  See: Powertrain Management/Computers and Control Systems/Testing and
Inspection/Diagnostic Trouble Code Descriptions/Safety Connect System

A --  CHECK FOR INTERMITTENT PROBLEMS  

Green Indicator Remains Off

CELLULAR COMMUNICATION: SAFETY CONNECT SYSTEM: GREEN INDICATOR REMAINS OFF
 - GREEN INDICATOR REMAINS OFF

DESCRIPTION

After the power switch on (IG), the DCM (Telematics Transceiver) will enter into a self check mode. The manual (SOS) switch red indicator will
illuminate for 2 seconds and turn off followed by the manual (SOS) switch green indicator illuminating and remaining on under normal operation. If
neither the red nor green indicators remain on, verification of the subscription should be performed.

INSPECTION PROCEDURE

PROCEDURE

1. CONFIRM GREEN INDICATOR COMES ON

(a) After the power switched on (IG) and the manual (SOS) switch red indicator has come on for 2 seconds, confirm that the manual (SOS)

Initial Inspection and Diagnostic Overview|Page 6059 > < Initial Inspection and Diagnostic Overview|Page 6057