16. INSTALL INVERTER TERMINAL COVER

CAUTION:
Wear insulating gloves.

NOTICE:
*

Make sure that the interlock are fully engaged.

*

Do not allow any foreign objects or water to enter the inverter with converter assembly.

(a) Using several steps, install and tighten the 11 bolts uniformly in the sequence shown in the illustration.

Torque : 8.0 Nm (82 kgf-cm, 71 in-lbf)

17. INSTALL NO. 1 INVERTER RESERVE TANK BRACKET

(a) Install the No. 1 inverter reserve tank bracket with the 2 bolts to the inverter with converter assembly.

Torque : 10 Nm (102 kgf-cm, 7 ft-lbf)

18. INSTALL INVERTER RESERVE TANK ASSEMBLY

(a) Install the inverter reserve tank with the bolt and nut to the No. 1 inverter reserve tank bracket.

Torque : 10 Nm (102 kgf-cm, 7 ft-lbf)

(b) Connect the 3 water hoses to the inverter reserve tank sub-assembly with the 3 hose clamps.

(c) Connect the hose to the clamp.

19. INSTALL NO. 3 INVERTER BRACKET

(a) Install the No. 3 inverter bracket with the bolt and nut.

Torque : 10 Nm (102 kgf-cm, 7 ft-lbf)