RX 450h AWD V6-3.5L (2GR-FXE) Hybrid (2011)
16. DISCONNECT NO. 3 WIRE FRAME
CAUTION:
Wear insulating gloves.
NOTICE:
*
Insulate the removed terminals with insulating tape.
*
Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.
(a) Remove the 4 bolts, and disconnect the No. 3 wire frame (high voltage cables of the hybrid battery) from the inverter with converter assembly.
(b) Disconnect the 3 harness clamps.
17. INSTALL INVERTER TERMINAL COVER
(a) Temporarily install the inverter cover with the 11 bolts to prevent any foreign objects or water from entering the inverter with converter
assembly.
18. SEPARATE RELAY BLOCK SUB-ASSEMBLY
(a) Disconnect the clamp, and release the relay block sub-assembly.
19. DISCONNECT MG ECU CONNECTOR
CAUTION:
Wear insulating gloves.
NOTICE:
*
Insulate the removed terminals with insulating tape.